Thermo-Time Switch
L-JETRONIC: TEST CHART
THERMO-TIME SWITCHMeasure:
Resistance between terminal "W" on thermo-time switch and ground.
Value:
0 Ohms with engine temperature below:
- 50 F (thermo-time switch 0 280 130 219)
- 56 F (thermo-time switch 0 280 130 221)
- 86 F (thermo-time switch 0 280 130 214)
Infinite resistance with engine temperature above:
- 68 F (thermo-time switch 0 280 130 219)
- 74 F (thermo-time switch 0 280 130 221)
- 104 F (thermo-time switch 0 280 130 214)
Deviation:
If resistance value lies outside of specification, thermo-time switch is defective.