Cold Start Valve
L-JETRONIC: TEST CHART
COLD START VALVEOperate:
Engine at idle speed with electrical plug disconnected from start valve.
Measure:
Voltage supply at cold start valve.
Value:
11-12.5 Volts between terminals 45 and 46 of the disconnected cold start valve plug with engine temperature below 86 F.
0 Volts between terminals as above with engine temperature above 104 F.
Deviation:
If values given are not reached, check thermo-time switch for proper function (see here). Check cables 45 and 46 for continuity.
Measure:
Resistance of start valve coil windings.
Value:
About 4 Ohms between terminals 45 and 46 of cold start valve.
Deviation:
If winding is open (infinite resistance) or shorted (no resistance), replace cold start valve.