| Symbol | Description | Track |
|---|---|---|
| B | Starter terminal 30 | 14 |
| E 1a | Light switch terminal 58b | 1 |
| E 13 | Temperature regulating switch (switching part) | 3 |
| E 13a | Temperature regulating switch (regulating part) | 5 |
| E 13b | Temperature regulating switch (electronic part) | 5, 6 |
| E 16 | Heater lever switch | 8 |
| F 16 | Flame switch | 13 |
| F 17 | Overheating switch | 16 |
| G 6 | Metering pump | 15 |
| J 8 | Relay | 6, 8, 13, 14, 15 |
| J 10 | Safety switch | 8, 9 |
| K 11 | Heater warning light | 3 |
| N 10 | Temperature sensor | 5 |
| N 11 | Ignition coil | 12 |
| O 1 | Contact breaker for ignition in combustion air blower | 12 |
| O 2 | Contact breaker for metering pump | 15 |
| Q 5a | Glow-spark plug (Glow element) | 10 |
| Q 5b | Glow-spark plug (Electrode) | 11 |
| S 9 | 9th fuse in fuse box | 3 |
| S 10 | 10th fuse in fuse box | 2 |
| S 16 | Main fuse (16 Amps; in fuse holder) | 14 |
| S 17 | Overheating fuse (8 Amps; in fuse holder) | 15 |
| T 1a | Wire connector, single (below rear seat bench) | 5 |
| T 1b | Wire connector, single (near frame tunnel) | 8 |
| T 2 | Wire connector, double (near heater blower) | 14 |
| T 4 | Wire connector on combustion air blower | 12, 13, 15, 16 |
| T 8a | Wire connector, eight connections (on dashboard, left) | 3, 4, 5, 6, 8 |
| T 8b | Wire connector, eight connections (in engine compartment, left, wagon) | 5, 10, 13, 14, 15, 16 |
| V 4 | Heater air blower | 14 |
| V 6 | Combustion air blower | 13 |
| 18 | Ground strap on frame | 10, 13, 16 |
The heater ignites within 60 seconds if the air drawn in is at room temperature. The start-up process is terminated by the flame switch (F 16).
Voltage can be measured at:
Relay (J8) operates contacts E-G, E-F and C-D.
The warm air motor (V 4) starts to work.
The combustion air blower motor (V 6) starts to work.
No voltage or a low voltage can be measured at:
Relay (J 8a) operates the contacts E-F and D-C.
Voltage can be measured at:
The glow element of the glow-spark plug (Q 5a) is energized. It warms the fuel/air-mixture to make it readily combustible. It is then ignited by the sparks from the glow-spark plug (Q 5a).
The metering pump (G 6) starts to deliver fuel. At every 33rd revolution of the combustion air motor (V 6) the metering pump (G 6) receives an impulse via the contact breaker (O 6).
When the heater has ignited and warmed up, the flame switch (F 16) operates the contacts C-NC.
The following are de-energized:
The safety switch (J 10) does not operate.
During regulation there are two voltages at terminal 5 of the temperature regulating switch (E 13b). These voltages are controlled by the temperature selection via the electronic circuitry (E 13b) and the temperature sensor (N 10). When the heater reaches the high heat output, the temperature sensor (N 10) records a high temperature and the temperature regulating switch (E 13b) indicates a high voltage at terminal 5 as the switching value for the relay (J 8a)
Voltage can be measured at:
The relay now separates the contacts E-F and D-C.
The following are de-energized:
The metering pump (G 6) stops delivering fuel and combustion stops. As the heater cools down and before the flame switch sensor tube can cool off sufficiently to close contacts C-N (less than 2 minutes), the temperature sensor (N 10) registers the lowered temperature and switches the heater back on.
No voltage or a low voltage can be measured at:
Relay (J 8a) reconnects the contacts E-F and D-C.
Voltage can be measured at:
The metering pump (G 6) resumes fuel delivery.
If the heater should overheat, the overheating switch (F 17) closes and causes a short circuit which blows the 8 Amp fuse (S 17).
This de-energizes:
The flame goes out and the run-on starts.
The safety switch (J 10) responds when the flame switch (F 16) holds the contacts C-NO for longer than roughly two to four minutes because combustion has not taken place in the heater or because the thermoswitch (12) is defective.
Voltage can be measured at:
The following are de-energized:
All connections in relay (J 8) are interrupted.
The combustion air motor (V 8) stops. The ignition coil (N 11) is de-energized. The hot air blower (V 4) stops.
The metering pump (G 6) stops delivering fuel.
Turn knob of temperature regulating switch (E 13) back to the stop position. Press heater lever switch down to open ground contact (E 16).
The following are de-energized:
All connections in relay (J 8) are interrrupted.
The run-on lasts for about two minutes at an ambient temperature of 20 C (68 F) and is shorter at lower temperatures. The run-on is necessary in order to clear all traces of gas from the heat exchanger and cool it down. The flame switch limits the run-on period.
The following is de-energized:
The metering pump (G 6) stops working.
Voltage can be measured at:
The combustion air motor (V 6) operates. The hot air blower (V 4) delivers air. When the heat exchanger has cooled down, the flame switch (F 16) operates contacts C-NO.
The following is de-energized:
Hot air blower (V 4) and combustion air blower (V 6) are de-energized and the run-on is finished.